Repository logo
 

Design optimisation of bare conductors for overhead line applications.

dc.contributor.advisorIjumba, Nelson Mutatina.
dc.contributor.advisorMuftic, Dzevad.
dc.contributor.authorMunilall, Anandran.
dc.date.accessioned2013-02-18T13:46:53Z
dc.date.available2013-02-18T13:46:53Z
dc.date.created2009
dc.date.issued2009
dc.descriptionThesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2009.en
dc.description.abstractThe South African economy is an emerging market and as such there is a continued and growing need for the efficient supply of cost effective electricity. The capital investment involved in the design, construction, installation and commissioning of overhead transmission line networks are high and so too are the subsequent maintenance and operation costs, incurred over their life cycle periods. The need to improve the electrical operating efficiency of existing and future electrical transmission networks, through the reduction of electrical losses, focused and motivated the research in this particular area. The results and findings produced by this research study show that the magnetic induction produced by the steel core in ACSR (Aluminium conductor, steel reinforced) conductors cause in increase in the ac power losses, associated ac-dc resistance ratio and the effective ac resistance of the conductor, whilst the conductor is energised during normal operation. More specifically, the key parameters that cause this increase in the effective ac resistance of the conductor, as a result of the magnetic induction produced by the steel core, are those of hysterisis and eddy current power losses in the steel core and an added power loss caused by the non-uniform redistribution of current in the layers of aluminum wires, due to the ‘transformer effect’. Therefore the addition of the conductor dc resistance value to the component resistances produced by the current redistribution and magnetic hysterisis & eddy current power losses, form the total effective ac conductor resistance. This is contrary to standard practice where assumption is made that the conductor ac and dc resistance values are equal. The factors which influence the magnetic induction, include amongst others; the ferromagnetic properties of the steel core, the physical construction of the conductor, the conductor operating/core temperature and the load current. In order to calculate the effective ac-resistance of multi-layer ACSR conductors a computer simulation program was developed, which was largely based on determining the impact of varying these key factors, by evaluating its effect on the ac resistance of the conductor. It was found through manipulation of these factors that the total effective ac resistance of the conductor could be reduced and significantly so with higher load currents. The conductor sample used in this research study is commonly known as TERN ACSR conductor in the South African market and it was shown that with practical changes in lay ratios or lay lengths, one is able to reduce the total effective ac resistance of the conductor and associated power losses. Several software simulation exercises were performed using the developed software simulation program, to ultimately produce a set of optimised lay-lengths (lay-ratios) for the TERN ACSR conductor, with the intention that these simulated parameters would be employed in the production of actual conductor samples. The intention going forward after the planned production trial runs would be to test these conductor samples to verify compliance, in meeting both electrical and mechanical performance requirements. It should be noted that the planned production trials and relevant conductor-testing processes did not form part of the scope of this research report but are processes that have been planned for in the near future. Although testing to IEC 61089 are post processes that are planned for outside of this research scope, the specification requirements of IEC61089 were incorporated into the various computer simulation exercises.en
dc.identifier.urihttp://hdl.handle.net/10413/8553
dc.language.isoen_ZAen
dc.subjectOverhead electric lines.en
dc.subjectElectric conductors.en
dc.subjectTheses--Electrical engineering.en
dc.titleDesign optimisation of bare conductors for overhead line applications.en
dc.typeThesisen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Munilall_Anandran_2009.pdf
Size:
696.04 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.64 KB
Format:
Item-specific license agreed upon to submission
Description: