dc.description.abstractLow-voltage switchgear and controlgear assemblies with a rated short-circuit withstand strength above 10 kA, are required, by law, to conform to the South African standard, SANS 1473-1 (Low Voltage Switchgear and Controlgear Assemblies: Part 1: Typetested, partially type-tested and specially tested assemblies with rated short-circuit withstand strength above lOkA). Standard SANS 1473-1 stipulates three categories of assemblies i.e. type-tested, partially type-tested and specially tested assemblies. The specially tested assembly is unique to the South African market, while the other two categories are stipulated in standard SANS IEC 60439-1 (Low Voltage Switchgear and Controlgear Assemblies: Part 1: Type-tested and partially type-tested assemblies), which is internationally accepted in many countries as the applicable low-voltage assembly standard. Standard SANS 1473-1 specifies seven type-tests for certification as a type-tested assembly (TTA), but specifies, at most, three type-tests for certification as a specially tested assembly (STA). The underlying purpose of a technical standard is to provide for the safety of people and property, with the purpose of the research being twofold: 1. To investigate if the testing requirements specified for a specially tested assembly (STA), in accordance with standard SANS 1473-1, are correctly applied, and do not pose any safety risks. 2. To investigate any safety risks that stem from the fact that four type-tests are excluded for verification as a specially tested assembly (STA), as opposed to the seven type tests required for verification as a type-tested assembly (TTA). The document highlights the technical inadequacies of an assembly that is certified as a STA, in accordance with standard SANS 1473-1, and the potential safety risks associated with this type of assembly classification.en
dc.identifier.urihttp://hdl.handle.net/10413/4201
dc.language.isoenen
dc.subjectElectric switchgear.en
dc.subjectAssembly line methods.en
dc.subjectManufacturing processes--Automation.en
dc.subjectManufacturing industries--South Africa.en
dc.subjectManufacturing industries--Quality control.en
dc.subjectTheses--Electrical engineering.en
dc.titleSafety implications of the introduction of a specially tested assembly into the South African national standard for low-voltage assemblies.en
dc.typeThesisen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bonner_Mark_2004.pdf
Size:
2.38 MB
Format:
Adobe Portable Document Format
Description:
Thesis.

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.64 KB
Format:
Item-specific license agreed upon to submission
Description: