Browsing by Author "Govender, Kamini."
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item Over-expression of FLO11 encoded mannoprotein in Saccharomyces cerevisiae.(2015) Govender, Kamini.; Govender, Patrick.; Pillay, Karen.Abstract available in PDF file.Item Sub/supercritical fluid chromatography purification of biologics.(2020) Govender, Kamini.; Naicker, Tricia.; Kruger, Hendrik Gerhardus.Peptide and protein drugs are highly versatile with numerous therapeutic properties such as anti-cancer, anti-diabetic, anti-hypertensive, and anti-microbial; which are therefore ideal candidates for the development of next-generation drugs. This is exemplified using these drugs for the treatment of diseases such as diabetes. Diabetes is one of the most prevalent non-communicable diseases worldwide. The rapid increase in the number of diabetic patients globally places a burden on current insulin manufacturers. The traditional reversed-phase high-performance liquid chromatography (RP-HPLC) purification methods of insulin and peptides are problematic, tedious with long run times of approximately 50 minutes, low yields employ harsh solvents such as acetonitrile, which has a negative impact on the environment. There is a need for a greener process for the purification of insulin and peptides. Sub/supercritical fluid chromatography (SFC) can provide the solution since it utilises greener mobile phases such as carbon dioxide (CO2) and methanol, which can be recycled. However, there is a paucity of knowledge regarding the SFC purification of human insulin and peptides. Therefore, this research study aimed to provide an efficient, innovative approach for the biosynthesis of human insulin and the SFC purification of biosynthesised human insulin, as well as the extension into the SFC purification of peptides. The background of these topics is presented in Chapter One. Chapter two (manuscript one) presents the development of a novel and more efficient method of human insulin biosynthesis in Escherichia coli (E. coli). Several of the conventional steps were eliminated. The crude biosynthesised protein sequence was verified using protein sequencing, which had a 100% similarity to the human insulin sequence. The biological activity of the biosynthesised human insulin was tested in vitro using a 3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyl tetrazolium bromide (MTT) assay. The biosynthesis of human insulin was conducted on a laboratory-scale basis; future studies should investigate scaling up of this method. Chapter three (manuscript two) was based on the SFC purification of the commercially available standard sample of human insulin and a crude biosynthesised sample of human insulin. The SFC purified standard the biosynthesised human insulin samples were detected and quantified using liquid chromatographymass spectrometry (LC-MS) and protein sequencing techniques. SFC columns, i.e., silica, 2’ ethyl pyridine, diol-HILIC, and the pentafluoro phenyl (PFP), were evaluated to determine the ideal column. The PFP column gave the best results since it displayed good peak shapes, resolution, retention factors, retention times, and the least relative standard deviation in comparison to the other columns. Therefore, the aforementioned column was selected for further analysis using the biosynthesised human insulin, whereby a column efficiency test was conducted on a semi-preparative scale, yielding 84% recovery. Subsequently, the biological activities of the SFC purified standard sample of human insulin and biosynthesised version were tested in vitro using a MTT assay. The results indicated that the biological activities of the standard and biosynthesised human insulin derivatives were retained subsequent to SFC purification. The biological activities were highly significant, with a p-value of < 0.0001. From chapter three, band broadening and phase separation peaks were experienced during SFC purification of the commercially available standard sample of human insulin and biosynthesised human insulin. Therefore, in Chapter four (manuscript three), a SFC purification method was developed to purify peptides at an analytical scale. A tetrapeptide [insulin β chain peptide (15-18)], octapeptide [angiotensin II], nonapeptide [insulin β chain peptide (15-23)] were purified using four SFC columns, i.e., PFP, diolHILIC, silica, and 2’ ethyl pyridine. Subsequently, the 2’ ethyl pyridine column was selected for further analysis based on the reproducibility, peak shapes, efficient separations and retention factors. The three peptides were monitored using LC-MS analysis. The successful peptide recoveries ranged from 80-102%. Chapter five pertains to the summary and conclusion drawn from the study and reflects on possible future endeavours. The present study was successful in providing a more affordable and innovative approach for the biosynthesis of human insulin. The work also successfully developed a rapid, greener, and more efficient method of SFC purifying biosynthesised human insulin and peptides as opposed to conventional HPLC purification methods. As far as we are aware, this study is the first of its kind to purify biosynthesised human insulin and this combination of peptides using SFC purification techniques. Future research studies can focus on the SFC purification of larger protein molecules and consider the use of custom columns and or other modifiers for the improvement of the isolation of other highly sought after biologics within the pharmaceutical industry.